Meanwell ELG-75-48 Specifications

Model ELG-75-48 
Output DC VOLTAGE 48V
CONSTANT CURRENT REGION 48V
RATED CURRENT 1.6A
RATED POWER 200VAC ~ 305VAC
76.8W
100VAC ~ 180VAC
60W
RIPPLE & NOISE (max.) 250 mVp-p
VOLTAGE TOLERANCE ±2.0%
LINE REGULATION ±0.5%
LOAD REGULATION ±0.5%
SETUP, RISE TIME 500ms, 100ms/115VAC, 230VAC
HOLD UP TIME (Typ.) 10ms/ 230VAC 10ms/ 115VAC(at full load)
Input VOLTAGE RANGE 100 ~ 305VAC 142 ~ 431VDC (Please refer to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR PF>=0.97/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC at full load
TOTAL HARMONIC DISTORTION THD< 20%(@load>=50%/115VC,230VAC; at load>=75%/277VAC)
EFFICIENCY (Typ.) 90.00%
AC CURRENT 0.7A / 115VAC 0.45A / 230VAC 0.38A/277VAC
INRUSH CURRENT (Typ. ) COLD START 50A(twidth=350μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER 5 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC
NO LOAD / STANDBY POWER CONSUMPTION No load power consumption <0.5W for Blank / A / Dx / D2-Type
Standby power consumption <0.5W for B / AB / DA-Type
LEAKAGE CURRENT <0.75mA / 277VAC
PROTECTION OVER CURRENT 95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed
OVER TEMPERATURE Shut down output voltage, re-power on to recover
OVER VOLTAGE 54-62V
Shut down output voltage, re-power on to recover
ENVIRONMENT WORKING TEMP ‘Tcase=-40 ~ +85 (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
MAX. CASE TEMP. Tcase=+85
WORKING HUMIDITY 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +80, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/ (0 ~ 60)
VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY &EMC SAFETY STANDARDS UL8750(type”HL”), CSA C22.2 No. 250.13-12; IEC/BS EN/EN/AS/NZS 61347-1, IEC/BS EN/EN/AS/NZS 61347-2-13 independent, BS EN/EN62384;EAC TP TC 004;BIS IS15885(for 12A/12DA/12B/24A/24B/24DA/36A/36B/42A/42B/48A/48B only); IP65 or IP67; GB19510.1, GB19510.14; KC61347-1,KC61347-2-13 approved
DALI STANDARDS Compliance to IEC62386-101,102,(207 by request) for DA Type only
WITHSTAND VOLTAGE I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
EMC EMISSION Compliance to BS EN/EN55015,BS EN/EN61000-3-2 Class C ( at load>=50%) ; BS EN/EN61000-3-3; GB17743, GB17625.1; EAC TP TC 020; KC KN15,KN61547
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV);EAC TP TC 020; KC KN15,KN61547
Others MTBF 3451.7K hrs min. Telcordia SR-332 (Bellcore) ;331.3K hrs min. MIL-HDBK-217F (25)
DIMENSION 180*63*35.5mm (L*W*H)
PACKING 0.8Kg;16pcs/13.4Kg/0.67CUFT

Meanwell ELG-75-48 Features

5 years warranty

 Class 2 power unit

Typical lifetime> 50000 hours

Metal housing design with functional Ground

 No load/Standby power consumption <0.5W

IP67/IP65 rating for indoor or outdoor installations

Constant Voltage + Constant Current mode output

Meanwell ELG-75-48 Applications

l  LED architectural lighting

l  Type HL” for use in Class l, Division 2 hazardous (Classified) location

Data

In stock (Vana-Tartu mnt 79A)

No

Brands

Input voltage

IP class

Out of Stock Delivery Time From Supplier

7-14 days

Max

Power consumption/Max power

Output voltage

Length (mm)

Based on 0 reviews

0.0 overall
0
0
0
0
0

Only logged in customers who have purchased this product may leave a review.

There are no reviews yet.